summaryrefslogtreecommitdiff
path: root/drivers/net/ethernet/renesas/rswitch.h
AgeCommit message (Collapse)Author
2024-12-19Merge git://git.kernel.org/pub/scm/linux/kernel/git/netdev/netJakub Kicinski
Cross-merge networking fixes after downstream PR (net-6.13-rc4). No conflicts. Adjacent changes: drivers/net/ethernet/renesas/rswitch.h 32fd46f5b69e ("net: renesas: rswitch: remove speed from gwca structure") 922b4b955a03 ("net: renesas: rswitch: rework ts tags management") Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2024-12-18net: renesas: rswitch: use generic MPSM operation for mdio C45Nikita Yushchenko
Introduce rswitch_etha_mpsm_op() that accepts values for MPSM register fields and executes the transaction. This avoids some code duptication, and can be used both for C45 and C22. Convert C45 read and write operations to use that. Signed-off-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com> Reviewed-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Tested-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Link: https://patch.msgid.link/20241216071957.2587354-5-nikita.yoush@cogentembedded.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2024-12-18net: renesas: rswitch: align mdio C45 operations with datasheetNikita Yushchenko
Per rswitch datasheet, software can know that mdio operation completed either by polling MPSM.PSME bit, or via interrupt. Instead, the driver currently polls for interrupt status bit. Although this still provides correct result, it requires additional register operations to clean the interrupt status bits, and generally looks wrong. Fix it to poll MPSM.PSME bit, as the datasheet suggests. Signed-off-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com> Reviewed-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Tested-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Link: https://patch.msgid.link/20241216071957.2587354-4-nikita.yoush@cogentembedded.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2024-12-18net: renesas: rswitch: use FIELD_PREP for remaining MPIC register fieldsNikita Yushchenko
Commit fb9e6039c325 ("net: renesas: rswitch: fix initial MPIC register setting") converted setting some MPIC fields to FIELD_PREP. To keep common style, do the same with mii bus related fields of the same register. Signed-off-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com> Reviewed-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Tested-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Link: https://patch.msgid.link/20241216071957.2587354-3-nikita.yoush@cogentembedded.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2024-12-15net: renesas: rswitch: rework ts tags managementNikita Yushchenko
The existing linked list based implementation of how ts tags are assigned and managed is unsafe against concurrency and corner cases: - element addition in tx processing can race against element removal in ts queue completion, - element removal in ts queue completion can race against element removal in device close, - if a large number of frames gets added to tx queue without ts queue completions in between, elements with duplicate tag values can get added. Use a different implementation, based on per-port used tags bitmaps and saved skb arrays. Safety for addition in tx processing vs removal in ts completion is provided by: tag = find_first_zero_bit(...); smp_mb(); <write rdev->ts_skb[tag]> set_bit(...); vs <read rdev->ts_skb[tag]> smp_mb(); clear_bit(...); Safety for removal in ts completion vs removal in device close is provided by using atomic read-and-clear for rdev->ts_skb[tag]: ts_skb = xchg(&rdev->ts_skb[tag], NULL); if (ts_skb) <handle it> Fixes: 33f5d733b589 ("net: renesas: rswitch: Improve TX timestamp accuracy") Signed-off-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com> Link: https://patch.msgid.link/20241212062558.436455-1-nikita.yoush@cogentembedded.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2024-12-12Merge git://git.kernel.org/pub/scm/linux/kernel/git/netdev/netJakub Kicinski
Cross-merge networking fixes after downstream PR (net-6.13-rc3). No conflicts or adjacent changes. Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2024-12-12net: renesas: rswitch: fix initial MPIC register settingNikita Yushchenko
MPIC.PIS must be set per phy interface type. MPIC.LSC must be set per speed. Do that strictly per datasheet, instead of hardcoding MPIC.PIS to GMII. Fixes: 3590918b5d07 ("net: ethernet: renesas: Add support for "Ethernet Switch"") Signed-off-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com> Reviewed-by: Michal Swiatkowski <michal.swiatkowski@linux.intel.com> Link: https://patch.msgid.link/20241211053012.368914-1-nikita.yoush@cogentembedded.com Signed-off-by: Paolo Abeni <pabeni@redhat.com>
2024-12-11net: renesas: rswitch: enable only used MFWD featuresNikita Yushchenko
Currently, rswitch driver does not utilize most of MFWD forwarding and processing features. It only uses port-based forwarding for ETHA ports, and direct descriptor forwarding for GWCA port. Update rswitch_fwd_init() to enable exactly that, and keep everything else disabled. Signed-off-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com> Reviewed-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Tested-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2024-12-09net: renesas: rswitch: remove speed from gwca structureNikita Yushchenko
This field is set but never used. GWCA is rswitch CPU interface module which connects rswitch to the host over AXI bus. Speed of the switch ports is not anyhow related to GWCA operation. Signed-off-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com> Reviewed-by: Michal Swiatkowski <michal.swiatkowski@linux.intel.com> Link: https://patch.msgid.link/20241206192140.1714-2-nikita.yoush@cogentembedded.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2023-12-10net: rswitch: Allow jumbo framesYoshihiro Shimoda
Allow jumbo frames by changing maximum MTU size and number of RX queues. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-12-10net: rswitch: Add jumbo frames handling for RXYoshihiro Shimoda
If this hardware receives a jumbo frame like 2KiB or more, it will be split into multiple queues. In the near future, to support this, add handling specific descriptor types F{START,MID,END}. However, such jumbo frames will not happen yet because the maximum MTU size is still default for now. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-12-10net: rswitch: Set GWMDNC registerYoshihiro Shimoda
To support jumbo frames, set GWMDNC register with acceptable maximum values for TX and RX. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-12-10net: rswitch: Add unmap_addrs instead of dma address in each descYoshihiro Shimoda
If the driver would like to transmit a jumbo frame like 2KiB or more, it should be split into multiple queues. In the near future, to support this, add unmap_addrs array to unmap dma mapping address instead of dma address in each TX descriptor because the descriptors may not have the top dma address. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-12-10net: rswitch: Use build_skb() for RXYoshihiro Shimoda
If this hardware receives a jumbo frame like 2KiB or more, it will be split into multiple queues. In the near future, to support this, use build_skb() instead of netdev_alloc_skb_ip_align(). Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-12-10net: rswitch: Use unsigned int for desc related array indexYoshihiro Shimoda
Array index should not be negative, so use unsigned int for descriptors related array index. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-10-19rswitch: Use unsigned int for port related array indexYoshihiro Shimoda
Array index should not be negative, so modify the condition of rswitch_for_each_enabled_port_continue_reverse() macro, and then use unsigned int instead. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Simon Horman <horms@kernel.org> Signed-off-by: Paolo Abeni <pabeni@redhat.com>
2023-10-03rswitch: Fix PHY station management clock settingYoshihiro Shimoda
Fix the MPIC.PSMCS value following the programming example in the section 6.4.2 Management Data Clock (MDC) Setting, Ethernet MAC IP, S4 Hardware User Manual Rev.1.00. The value is calculated by MPIC.PSMCS = clk[MHz] / (MDC frequency[MHz] * 2) - 1 with the input clock frequency from clk_get_rate() and MDC frequency of 2.5MHz. Otherwise, this driver cannot communicate PHYs on the R-Car S4 Starter Kit board. Fixes: 3590918b5d07 ("net: ethernet: renesas: Add support for "Ethernet Switch"") Reported-by: Tam Nguyen <tam.nguyen.xa@renesas.com> Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Tested-by: Kuninori Morimoto <kuninori.morimoto.gx@renesas.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Link: https://lore.kernel.org/r/20230926123054.3976752-1-yoshihiro.shimoda.uh@renesas.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2023-09-14net: renesas: rswitch: Add spin lock protection for irq {un}maskYoshihiro Shimoda
Add spin lock protection for irq {un}mask registers' control. After napi_complete_done() and this protection were applied, a lot of redundant interrupts no longer occur. For example: when "iperf3 -c <ipaddr> -R" on R-Car S4-8 Spider Before the patches are applied: about 800,000 times happened After the patches were applied: about 100,000 times happened Fixes: 3590918b5d07 ("net: ethernet: renesas: Add support for "Ethernet Switch"") Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Simon Horman <horms@kernel.org> Signed-off-by: Paolo Abeni <pabeni@redhat.com>
2023-08-08net: renesas: rswitch: Add runtime speed change supportYoshihiro Shimoda
The latest SoC version can support runtime speed change. So, add detect SoC version by using soc_device_match() and then reconfigure the hardware of this and SerDes if needed. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Simon Horman <horms@kernel.org> Link: https://lore.kernel.org/r/20230807003231.1552062-2-yoshihiro.shimoda.uh@renesas.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2023-06-10net: renesas: rswitch: Use hardware pause featuresYoshihiro Shimoda
Since this driver used the "global rate limiter" feature of GWCA, the TX performance of each port was reduced when multiple ports transmitted frames simultaneously. To improve performance, remove the use of the "global rate limiter" feature and use "hardware pause" features of the following: - "per priority pause" of GWCA - "global pause" of COMA Note that these features are not related to the ethernet PAUSE frame. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Maciej Fijalkowski <maciej.fijalkowski@intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-03-17net: renesas: rswitch: Fix GWTSDIE register handlingYoshihiro Shimoda
Since the GWCA has the TX timestamp feature, this driver should not disable it if one of ports is opened. So, fix it. Reported-by: Phong Hoang <phong.hoang.wz@renesas.com> Fixes: 33f5d733b589 ("net: renesas: rswitch: Improve TX timestamp accuracy") Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-02-10net: renesas: rswitch: Improve TX timestamp accuracyYoshihiro Shimoda
In the previous code, TX timestamp accuracy was bad because the irq handler got the timestamp from the timestamp register at that time. This hardware has "Timestamp capture" feature which can store each TX timestamp into the timestamp descriptors. To improve TX timestamp accuracy, implement timestamp descriptors' handling. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Alexander Duyck <alexanderduyck@fb.com> Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2023-02-10net: renesas: rswitch: Remove gptp flag from rswitch_gwca_queueYoshihiro Shimoda
In the previous code, the gptp flag was completely related to the !dir_tx in struct rswitch_gwca_queue because rswitch_gwca_queue_alloc() was called below: < In rswitch_txdmac_alloc() > err = rswitch_gwca_queue_alloc(ndev, priv, rdev->tx_queue, true, false, TX_RING_SIZE); So, dir_tx = true, and gptp = false. < In rswitch_rxdmac_alloc() > err = rswitch_gwca_queue_alloc(ndev, priv, rdev->rx_queue, false, true, RX_RING_SIZE); So, dir_tx = false, and gptp = true. In the future, a new queue handling for timestamp will be implemented and this gptp flag is confusable. So, remove the gptp flag. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Alexander Duyck <alexanderduyck@fb.com> Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2023-02-10net: renesas: rswitch: Move linkfix variables to rswitch_gwcaYoshihiro Shimoda
To improve readability, move linkfix related variables to struct rswitch_gwca. Also, rename function names "desc" with "linkfix". Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Alexander Duyck <alexanderduyck@fb.com> Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2023-02-10net: renesas: rswitch: Rename rings in struct rswitch_gwca_queueYoshihiro Shimoda
To add a new ring which is really related to timestamp (ts_ring) in the future, rename the following members to improve readability: ring --> tx_ring ts_ring --> rx_ring Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Alexander Duyck <alexanderduyck@fb.com> Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2023-02-03net: renesas: rswitch: Convert to phy_deviceYoshihiro Shimoda
Intended to set phy_device->host_interfaces by phylink in the future. But there is difficult to implement phylink properly, especially supporting the in-band mode on this driver because extra initialization is needed after linked the ethernet PHY up. So, convert to phy_device from phylink. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-02-03net: renesas: rswitch: Simplify struct phy * handlingYoshihiro Shimoda
Simplify struct phy *serdes handling by keeping the valiable in the struct rswitch_device. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2023-01-20net: ethernet: renesas: rswitch: Fix ethernet-ports handlingYoshihiro Shimoda
If one of ports in the ethernet-ports was disabled, this driver failed to probe all ports. So, fix it. Fixes: 3590918b5d07 ("net: ethernet: renesas: Add support for "Ethernet Switch"") Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Jiri Pirko <jiri@nvidia.com> Reviewed-by: Jacob Keller <jacob.e.keller@intel.com> Link: https://lore.kernel.org/r/20230120001959.1059850-1-yoshihiro.shimoda.uh@renesas.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-11-08net: ethernet: renesas: rswitch: Fix endless loop in error pathsYoshihiro Shimoda
Coverity reported that the error path in rswitch_gwca_queue_alloc_skb() has an issue to cause endless loop. So, fix the issue by changing variables' types from u32 to int. After changed the types, rswitch_tx_free() should use rswitch_get_num_cur_queues() to calculate number of current queues. Reported-by: coverity-bot <keescook+coverity-bot@chromium.org> Addresses-Coverity-ID: 1527147 ("Control flow issues") Fixes: 3590918b5d07 ("net: ethernet: renesas: Add support for "Ethernet Switch"") Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Link: https://lore.kernel.org/r/20221107081021.2955122-1-yoshihiro.shimoda.uh@renesas.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-11-02net: ethernet: renesas: rswitch: Add R-Car Gen4 gPTP supportYoshihiro Shimoda
Add R-Car Gen4 gPTP support into the rswitch driver. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2022-11-02net: ethernet: renesas: Add support for "Ethernet Switch"Yoshihiro Shimoda
Add initial support for Renesas "Ethernet Switch" device of R-Car S4-8. The hardware has features about forwarding for an ethernet switch device. But, for now, it acts as ethernet controllers so that any forwarding offload features are not supported. So, any switchdev header files and DSA framework are not used. Signed-off-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>