summaryrefslogtreecommitdiff
path: root/drivers/net/wireless/ath/ath11k/thermal.c
AgeCommit message (Collapse)Author
2020-08-26net: ath11k: constify ath11k_thermal_opsRikard Falkeborn
The only usage of ath11k_thermal_ops is to pass its address to thermal_cooling_device_register() which takes a const pointer. Make it const to allow the compiler to put it in read-only memory. Signed-off-by: Rikard Falkeborn <rikard.falkeborn@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2020-05-19ath11k: Fix some resource leaks in error path in 'ath11k_thermal_register()'Christophe JAILLET
If 'thermal_cooling_device_register()' fails, we must undo what has been allocated so far. So we must go to 'err_thermal_destroy' instead of returning directly In case of error in 'ath11k_thermal_register()', the previous 'thermal_cooling_device_register()' call must also be undone. Move the 'ar->thermal.cdev = cdev' a few lines above in order for this to be done in 'ath11k_thermal_unregister()' which is called in the error handling path. Fixes: 2a63bbca06b2 ("ath11k: add thermal cooling device support") Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr> Signed-off-by: Kalle Valo <kvalo@codeaurora.org> Link: https://lore.kernel.org/r/20200513201454.258111-1-christophe.jaillet@wanadoo.fr
2020-03-11ath11k: add thermal sensor device supportPradeep Kumar Chitrapu
Temperature sensor generates electrical analog voltage from temperature of each chain. The analog voltage is converted to digital value through ADC. For reading temperature values fom user space, hw monitoring device is used. Whenever the user requests for current temperature, the driver sends WMI command and wait for response. For reading temperature, cat /sys/class/ieee80211/phy*/device/hwmon/hwmon2/temp1_input Signed-off-by: Pradeep Kumar Chitrapu <pradeepc@codeaurora.org> Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
2020-03-11ath11k: add thermal cooling device supportPradeep Kumar Chitrapu
Thermal cooling device support is added to control the temperature by throttling the data transmission for the given duration. Throttling is done by suspending all data tx queues by given percentage of time. The thermal device allows user to configure duty cycle. Throttling can be disabled by setting the duty cycle to 0. The cooling device can be found under /sys/class/thermal/cooling_deviceX/. Corresponding soft link to this device can be found under phy folder. /sys/class/ieee80211/phy*/device/cooling_device. To set duty cycle as 40%, echo 40 >/sys/class/ieee80211/phy*/device/cooling_device/cur_state Signed-off-by: Pradeep Kumar Chitrapu <pradeepc@codeaurora.org> Signed-off-by: Kalle Valo <kvalo@codeaurora.org>